How to do PROMETHEE II step by step: preference functions and net flows
PROMETHEE II step by step: pairwise differences, the six preference functions, thresholds, the preference index, and positive, negative and net flows.
CKR team · · 10 min read
PROMETHEE II compares every pair of alternatives on every criterion, turns each difference into a preference degree between 0 and 1 with a preference function chosen for that criterion, and weights and sums those degrees into a preference index π(a, b). Each alternative’s positive flow φ⁺ (how much it outranks the others) and negative flow φ⁻ (how much it is outranked) are averaged from π, and the net flow φ = φ⁺ − φ⁻ gives a complete ranking. The choice of preference function and its thresholds can change the result and must be justified.
The short version
- 01For each criterion choose a preference function: the usual criterion (any advantage is full preference) or one with an indifference threshold q and a preference threshold p.
- 02π(a, b) = Σ wⱼ·Pⱼ(a, b); φ⁺(a) and φ⁻(a) are the averages of a’s row and column of π, and φ(a) = φ⁺ − φ⁻.
- 03With the usual criterion the suppliers rank A (φ = 0.207), C (0.155), D (−0.080), B (−0.282). With linear functions and sensible thresholds, C moves ahead of A (0.178 against 0.154).
- 04PROMETHEE I, which keeps φ⁺ and φ⁻ separate, shows A and C as incomparable under the linear functions: C is better on φ⁺ and A on φ⁻.
How does PROMETHEE differ from TOPSIS and VIKOR?
PROMETHEE, the Preference Ranking Organisation METHod for Enrichment Evaluations, belongs to the outranking family of methods. It was introduced by Brans and Vincke (1985) and developed by Brans, Vincke and Mareschal (1986). Methods such as TOPSIS and VIKOR measure each alternative’s distance from an ideal. PROMETHEE instead compares alternatives with each other, pair by pair, criterion by criterion, and asks how strongly one is preferred to the other.
This has two practical consequences. First, there is no normalisation: differences are judged in the criterion’s own units, through a preference function that says how big a difference must be to matter. Second, a small advantage need not count as a full preference, which suits criteria measured with error. PROMETHEE I gives a partial ranking that can leave some alternatives incomparable; PROMETHEE II, the subject of this tutorial, gives a complete ranking by net flow.
- 01Pairwise differencesFor every ordered pair (a, b) and criterion j, the difference dⱼ(a, b), oriented so that positive favours a.
- 02Preference degreesPⱼ(a, b) = Fⱼ(dⱼ(a, b)), between 0 and 1, from the preference function chosen for criterion j.
- 03Preference indexπ(a, b) = Σⱼ wⱼ Pⱼ(a, b).
- 04Outranking flowsφ⁺(a) = average of π(a, ·); φ⁻(a) = average of π(·, a).
- 05Net flow and rankingφ(a) = φ⁺(a) − φ⁻(a); rank from highest to lowest.
What data will we use?
The four suppliers and the AHP weights from the VIKOR tutorial, so that TOPSIS, VIKOR and PROMETHEE can be compared on the same data. Cost (dollars per unit) and Delivery (days) are to be minimised; Quality and Service (ratings out of 10) are to be maximised.
| Supplier | Cost ($/unit) | Quality (1–10) | Delivery (days) | Service (1–10) |
|---|---|---|---|---|
| A | 250 | 8 | 12 | 7 |
| B | 200 | 6 | 15 | 8 |
| C | 300 | 9 | 10 | 6 |
| D | 275 | 7 | 8 | 9 |
| Weight | 0.3135 | 0.4967 | 0.1213 | 0.0685 |
| Direction | min | max | min | max |
Step 1: which preference function should each criterion use?
A preference function F turns a difference d into a preference degree P between 0 and 1. Brans, Vincke and Mareschal (1986) proposed six generalised criteria, which cover most practical situations.
| Type | Name | Parameters | P(d) for d > 0 |
|---|---|---|---|
| I | Usual | none | 1 for any positive difference |
| II | U-shape (quasi-criterion) | q | 0 if d ≤ q, otherwise 1 |
| III | V-shape (linear preference) | p | d/p if d ≤ p, otherwise 1 |
| IV | Level | q, p | 0 if d ≤ q; 1/2 if q < d ≤ p; 1 if d > p |
| V | Linear with indifference | q, p | 0 if d ≤ q; (d − q)/(p − q) if q < d ≤ p; 1 if d > p |
| VI | Gaussian | s | 1 − exp(−d²/(2s²)) |
Note. P(d) = 0 for d ≤ 0 in every type. q is the indifference threshold (the largest difference considered negligible), p the preference threshold (the smallest difference considered decisive).
The usual criterion suits qualitative scales where any difference is meaningful. For measured criteria, type V is the most common choice: differences below q are ignored, differences above p count fully, and preference grows linearly in between. The thresholds should come from the decision context, not from the data. Here the purchasing team said that price differences under $10 a unit do not matter and that $60 or more is decisive; for delivery, one day is negligible and five days decisive; for the two 1–10 ratings, any difference counts and two points is decisive.
- Usual
- Linear
Show the data
| Price advantage d ($/unit) | Usual | Linear |
|---|---|---|
| 0 | 0 | 0 |
| 5 | 1 | 0 |
| 10 | 1 | 0 |
| 20 | 1 | 0.2 |
| 30 | 1 | 0.4 |
| 40 | 1 | 0.6 |
| 50 | 1 | 0.8 |
| 60 | 1 | 1 |
| 70 | 1 | 1 |
| 80 | 1 | 1 |
Step 2: how do you compute the preference index?
For each ordered pair (a, b) and each criterion, compute the difference in the direction of preference: aⱼ − bⱼ for a criterion to maximise, bⱼ − aⱼ for one to minimise. Apply the criterion’s preference function, multiply by the weight, and sum over the criteria.
Take A against C under the linear functions. A is $50 cheaper, so P = (50 − 10)/(60 − 10) = 0.8 and the weighted contribution is 0.3135 × 0.8 = 0.2508. A is worse on Quality and Delivery, so those contribute 0. A is one point better on Service, which gives P = 1/2 = 0.5 and a contribution of 0.0343. So π(A, C) = 0.2851. In the other direction C is one point better on Quality (P = 0.5, contribution 0.2483) and two days faster on Delivery (P = (2 − 1)/(5 − 1) = 0.25, contribution 0.0303), so π(C, A) = 0.2787. The two are close: each supplier is preferred to the other to about the same degree.
| A | B | C | D | |
|---|---|---|---|---|
| A | — | 0.5574 | 0.2851 | 0.3424 |
| B | 0.2851 | — | 0.3820 | 0.3135 |
| C | 0.2787 | 0.6180 | — | 0.4967 |
| D | 0.1595 | 0.4039 | 0.1929 | — |
Step 3: how do you compute the outranking flows?
| Supplier | φ⁺ usual | φ⁻ usual | φ usual | φ⁺ linear | φ⁻ linear | φ linear |
|---|---|---|---|---|---|---|
| A | 0.6034 | 0.3966 | 0.2068 | 0.3949 | 0.2411 | 0.1539 |
| B | 0.3592 | 0.6408 | −0.2817 | 0.3269 | 0.5264 | −0.1996 |
| C | 0.5776 | 0.4224 | 0.1551 | 0.4645 | 0.2866 | 0.1778 |
| D | 0.4599 | 0.5401 | −0.0803 | 0.2521 | 0.3842 | −0.1321 |
Show the data
| Supplier | Net flow φ |
|---|---|
| C | 0.1778 |
| A | 0.1539 |
| D | -0.1321 |
| B | -0.1996 |
Why does the preference function change the winner?
Under the usual criterion, A ranks first (φ = 0.207) and C second (0.155). Under the linear functions the two swap: C 0.178, A 0.154. The cause is the size of A’s advantages. Against D, A is $25 cheaper and one point better on Quality. The usual criterion counts both as full preferences, so π(A, D) = 0.810. The linear functions count them as (25 − 10)/50 = 0.3 and 1/2 = 0.5, and π(A, D) falls to 0.342. C’s main advantage over D is two points on Quality, which is decisive under both functions, so π(C, D) stays at 0.497. A’s lead was built on many small differences, and once small differences count for less, it disappears. The order of D and B is the same in both.
This is not a weakness of PROMETHEE; it is the method doing what it is designed to do, making the decision-maker state how large a difference must be to matter. It does mean that the thresholds are part of the model and must be reported and justified like the weights. A sensitivity check that varies q and p within plausible ranges is good practice.
How sensitive is the result to the Cost threshold?
Since the thresholds decide the winner, it is worth testing them in the same way as weights. Keeping q = $10 for Cost and every other threshold fixed, the preference threshold p for Cost was varied from $20 to $100. The chart shows the net flows of A and C.
- A
- C
Note. The two lines cross at about p = $53. D and B stay third and fourth throughout.
Show the data
| Preference threshold p for Cost ($/unit) | A | C |
|---|---|---|
| 20 | 0.227 | 0.0838 |
| 30 | 0.2009 | 0.1099 |
| 40 | 0.1748 | 0.136 |
| 50 | 0.1617 | 0.1491 |
| 60 | 0.1539 | 0.1778 |
| 70 | 0.1486 | 0.197 |
| 80 | 0.1449 | 0.2107 |
| 90 | 0.1421 | 0.2209 |
| 100 | 0.1399 | 0.2289 |
A ranks first while p is below about $53, and C above it. The jump between $50 and $60 is where p passes the $50 price gap between A and C: below it that gap is a full preference for A, above it only a partial one. A purchasing team that considers a $50 difference decisive should prefer A; one that needs more than about $53 to be fully convinced should prefer C. Stating the result this way turns a technical parameter into a question the decision-maker can answer.
What does PROMETHEE I add?
PROMETHEE I ranks by φ⁺ and φ⁻ separately and only says that a outranks b when a is at least as good on both. Under the linear functions C has the higher positive flow (0.465 against 0.395) but A has the lower negative flow (0.241 against 0.287). Neither outranks the other, so PROMETHEE I declares A and C incomparable. That is a useful warning: the complete ranking of PROMETHEE II puts C first, but only by aggregating two flows that point in different directions. Under the usual criterion A is better on both flows and outranks C in PROMETHEE I as well.
- Net-flow gap between C and A (linear)
- 0.024
- Better positive flow φ⁺
- C
- Better negative flow φ⁻
- A
How do the three methods compare on this data?
| Method | Ranking | Note |
|---|---|---|
| TOPSIS | C, A, D, B | C leads A by 0.022 in closeness |
| VIKOR (v = 0.5) | A, C, D, B | Compromise set {A, C} |
| PROMETHEE II, usual | A, C, D, B | A leads by 0.052 in net flow |
| PROMETHEE II, linear | C, A, D, B | A and C incomparable in PROMETHEE I |
All four agree that D is third and B last. They disagree on the order of A and C, and every one of them signals in its own way that the two are close. A study that ran only one of these methods would report a clear winner; the comparison shows that the honest conclusion is a choice between A and C that depends on how much weight is given to price. CKR’s robustness checks automate this comparison with Spearman’s and Kendall’s rank correlations.
When should you choose PROMETHEE?
PROMETHEE suits decisions where the criteria are measured in different units and where small differences should not count as full preferences. Because it compares alternatives pair by pair, it also suits situations in which the decision-makers think in terms of “how much better is this one than that one” rather than “how close is this one to perfect”. Its thresholds give experts a way to express measurement error and indifference directly, which distance-based methods such as TOPSIS cannot do.
It is less suitable when the number of alternatives is large and the thresholds cannot be justified, because every pair must be compared and an arbitrary threshold weakens the result. When there is no basis for thresholds, the usual criterion is a defensible default, but then the method treats a one-dollar and a hundred-dollar difference alike, and that limitation should be acknowledged in the paper.
How do you report PROMETHEE?
Report the decision matrix, weights and directions; the preference function chosen for each criterion with its thresholds and the reason for them; the preference index matrix or at least the flows; the PROMETHEE II ranking; and, if the leaders are close, the PROMETHEE I result. For the suppliers: “With linear preference functions (Cost q = $10, p = $60), supplier C had the highest net flow (0.178), followed closely by A (0.154); PROMETHEE I found A and C incomparable, and A ranked first when the Cost preference threshold was below about $53.”
Which mistakes are common in PROMETHEE studies?
- Using the usual criterion for measured data without saying why, so that negligible differences count as full preferences.
- Choosing thresholds from the data (for example the standard deviation of each column) without a decision-related reason.
- Orienting the differences the wrong way for criteria to minimise.
- Dividing by m instead of m − 1 when averaging the flows. The ranking is unchanged but the values are not comparable with other studies.
- Reporting PROMETHEE II alone when PROMETHEE I shows incomparabilities among the leading alternatives.
Questions people ask
Do PROMETHEE weights need to sum to 1?
Yes, by convention. The preference index is then between 0 and 1 and the net flows between −1 and 1.
Does PROMETHEE need normalisation?
No. Differences are judged in each criterion’s own units through its preference function, so criteria in dollars, days and ratings can be combined directly.
What is GAIA?
GAIA is a visual companion to PROMETHEE that projects the alternatives and criteria onto a plane by principal component analysis, showing which criteria conflict. It does not change the ranking.
How do I choose q and p?
Ask the decision-maker: q is the largest difference they would ignore and p the smallest they would consider decisive. Measurement error is a good guide for q.
Can PROMETHEE suffer from rank reversal?
Yes. Adding or removing an alternative changes the flows, because they are averages over all pairs, and can reverse the order of others.
References
Brans, J. P., & Vincke, Ph. (1985). A preference ranking organisation method: The PROMETHEE method for multiple criteria decision-making. Management Science, 31(6), 647–656. https://doi.org/10.1287/mnsc.31.6.647
Brans, J. P., Vincke, Ph., & Mareschal, B. (1986). How to select and how to rank projects: The PROMETHEE method. European Journal of Operational Research, 24(2), 228–238. https://doi.org/10.1016/0377-2217(86)90044-5
CKR team · Chakaralaya Analytics
How this was checked. The usual-criterion preference matrix and flows were computed with CKR’s PROMETHEE. The linear-criterion results were computed with a separate script that reproduces CKR’s usual-criterion results exactly when given the usual function; the worked A–C comparison was checked by hand. References were checked against Crossref.